ROV Installed Sub-Sea Flange Clamp


ROV Installed Sub-Sea Flange Clamp

 

 

Clamp designed for ROV deployment and installation

 

 

 

 

 

 

 

 

Lower half of clamp is rotated into line by actuator – then bolts are inserted

 

 

 

 

 

 

 

 

Then ROV positions clamp around the flange before the bolts are tightened

 

 

 

 

 

 

ROV Installed Sub-Sea Flange Clamp

Outline of Problem:

10 inch nominal bore compact flange on a water injection system found to be leaking badly

Design Pressure was 197 bar (2860 psi)

Defect was believed to be substantial

  • Of an area equivalent to that of a 30mm diameter hole

Water Depth was approx. 500m (1600 ft)

  • Too deep for divers – clamp had to be flown, installed and injected by a ROV (Remote Operated Vehicle)

Furmanite - 80 Years of Innovation & Counting

Leak Sealing process developed leak-sealing-developed_thumb 01/01/1920

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
First DIY Leak-Sealing Kit old-furmanite-leak-sealing-equipment 01/01/1924

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Long Standing Relationships Sales-Brochure-1926_thumb 01/01/1926

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Use of Furmanite Leak Sealing Kits leak-sealing-10 11/01/1926

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
1st Patent is filed in 1927 furmanite-patents1 01/01/1927

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Furmanite moves Overseas Liverpool-Exibition_thumb 06/01/1927

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Costs of a steam leak Sales-Brochure-1926-pg-8_thumb 06/01/1928

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Furmanite is thinking global furmanite-the-skys-the-limit_thumb 01/01/1929

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Technology Development leak-sealing-diagram 11/22/1934

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Growing Furmanite purchase-letter_thumb 05/01/1960

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
New Direction New-Technology_thumb 01/01/1966

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Never compromise on the high quality Company-History-July-1979_thumb 07/01/1979

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Best in the business were called NASA---Discovery-Team_thumb 09/01/1988

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Start of Modern Furmanite company-overview 11/22/1991

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Acquisition-GSG Division Acquisition-GSG-Division_thumb 01/13/2006

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Corporate Name Change Corporate-Name-Change_thumb 01/13/2007

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More
Acquisition of SLM Acquisition-of-SLM_thumb 04/13/2011

10 inch nominal bore compact flange on a water injection system found to be leaking badly…

More

Contact Us

  • Note: Forms may be submitted only once per webpage session.

Email Page